Liquid-Gas Eductors and Water Jet Vacuum Pumps
Liquid-gas eductor specifications, suction performance, applications, and water jet vacuum pump data.
Liquid Jets Gas Eductor
GW52000 Air Suction Performance Data
| PI | 0.7 | 1.1 | 1.4 | 2.1 | 2.8 | 3.5 | 4.2 | 4.9 | 5.6 |
|---|---|---|---|---|---|---|---|---|---|
| PI | Qs | ||||||||
| 0.00 | 5.2 | 6.3 | 7.3 | 9.0 | 10.3 | 11.6 | 12.7 | 13.7 | 14.6 |
| 0.07 | 4.1 | 5.5 | 6.6 | 8.4 | 9.8 | 11.1 | 12.3 | 13.3 | 14.3 |
| 0.14 | 2.9 | 4.6 | 5.9 | 7.8 | 9.3 | 10.7 | 11.9 | 12.9 | 13.9 |
| 0.21 | 1.5 | 3.6 | 5.0 | 7.2 | 8.8 | 10.2 | 11.4 | 12.5 | 13.6 |
| 0.28 | 2.5 | 4.2 | 6.5 | 8.3 | 9.8 | 11.0 | 12.2 | 13.2 | |
| 0.35 | 1.1 | 3.2 | 5.8 | 7.7 | 9.3 | 10.6 | 11.8 | 12.9 | |
| 0.49 | 0.7 | 4.3 | 6.5 | 8.3 | 9.7 | 11.0 | 12.1 | ||
| 0.79 | 1.5 | 4.5 | 6.6 | 8.3 | 9.7 | 10.9 | |||
| 1.06 | 3.3 | 5.5 | 7.3 | 8.8 | |||||
| 1.41 | 2.1 | 4.3 | 6.4 | ||||||
| 1.76 | 1.0 | 3.5 | |||||||
| Qi | 3.2 | 3.9 | 4.5 | 5.5 | 6.3 | 7.1 | 7.7 | 8.3 | 8.9 |
| Wp | 0.1 | 0.1 | 0.2 | 0.3 | 0.5 | 0.7 | 0.9 | 1.1 | 1.3 |
| Model | GW52000-25 | GW52000-50 | GW52000-80 | GW52000-100 | GW52000-125 | GW52000-150 | GW52000-200 |
|---|---|---|---|---|---|---|---|
| Factor | 0.25 | 1 | 2.56 | 4 | 6.3 | 9 | 16 |
| Terminology | Pi(Motive pressure) | Pc(Outlet pressure) | Qi(Motive Flow) | Qs(Suction volume) | Wp(Suction Water Power) | Ps(Suction pressure) |
|---|---|---|---|---|---|---|
| unit | barg | barg | m3/h | m3/h | kw | 1bar |
Capacity=(Data of GW52000-50)*f
The data listed in the table are standard, if customer's condition deviates from the above please contact us to satisfy the requirement
Liquid Jets Gas Eductor Applications
Gas evacuation:
In many industries and civil practices there are needs to evacuate gas from hermetic space. Priming of centrifugal pump with LJG eductor is one of the various uses. The volume being primed are generally small, so a small quantity of fluid (pressurized water/air)can be applied as motive flow of the eductor.GW LJG eductor is also a safe option where it is dangerous to use power driven exhaust.
Maintaining pressure:
Some apparatus need to keep their internal pressure within a certain extend during operation, meanwhile, there is gas produced or entrained during the process. In this case, GW LJG can be utilized to exhaust gas and keep the pressure at the expected value. The above figure shows an example which is a MBR apparatus for wastewater treatment: When pressure rises in the gas-water separator, a differential pressure signal is given to a motive flow valve which automatically opens and the LJG eductor is activated to draw gas from the separator until the pressure drops to the minus desired point. This configuration not only saves space and investment but also energy since the driving fluid sources (pressure air/water)are always available on-site
Water Jet Vacuum Pumps
Water Jet Vacuum Performance Data
| Water jet vacuum pump model | GW52000-25 | GW52000-50 | GW52000-100 | GW52000-150 | GW52000-200 | GW52000-250 |
|---|---|---|---|---|---|---|
| Suction and outlet dimension | DN25 | DN50 | DN100 | DN150 | DN200 | DN250 |
| Water pressure(mH2O) | 25 | 25 | 25 | 25 | 25 | 25 |
| Water volume(m3/h) | 1.7 | 6.6 | 26 | 60 | 106 | 165 |
| Vacuum(bar) | 0.03 | 0.03 | 0.03 | 0.03 | 0.03 | 0.03 |
| Ave.suction rate(m3/h)) | 1.2 | 5 | 20 | 45 | 79 | 124 |
| Max.suction rate(m3/h) | 2.0 | 8 | 33 | 73 | 130 | 203 |
| Water power(Kw) | 0.11 | 0.44 | 1.78 | 4.00 | 7.11 | 11.1 |
| Suction volume per 10 minutes(L) | 55 | 220 | 900 | 2000 | 3500 | 5500 |
| Note:Suction rates is inclusive of saturated vapor | ||||||
Green Water Technology Co.,Ltd