Home

Library

Online Technical Manual

Gas Jet Eductor Technical Data

Gas Jet Eductor Technical Data

Gas-gas, gas-water, gas-solid, and high-pressure gas jet eductor performance data.

Gas Jets Water Eductor

GW62000 Gas Jet Water Eductor Performance Data

Pc 1.04 1.08 1.12 1.16 1.20 1.40 1.60 1.80
Pi Qi Gi Suction Volume
2 85 1.2 601 347 76
2.5 107 1.5 760 570 364 141
3 128 1.8 862 715 553 378 189
4 171 2.4 984 888 783 667 541
5 213 3.0 1047 984 913 833 745
6 256 3.6 1081 1039 991 935 874 745
7 299 4.2 1096 1070 1038 1000 956 649
8 341 4.8 1099 1085 1066 1041 1011 785 429
9 384 5.4 1095 1090 1080 1066 1048 884 606
10 427 6.0 1084 1086 1080 1078 1068 956 741 422

Gas Jets Solids Eductor

GW62000 Gas Jets Solids Eductor Performance Data

OutLet Pressure 1.04 1.08 1.12 1.16 1.20 1.40 1.60 1.80
Pi Qi Gi Suction Volume
2 85 1.2 601 347 76
2.5 107 1.5 760 570 364 141
3 128 1.8 862 715 553 378 189
4 171 2.4 984 888 783 667 541
5 213 3.0 1047 984 913 833 745
6 256 3.6 1081 1039 991 935 874 745
7 299 4.2 1096 1070 1038 1000 956 649
8 341 4.8 1099 1085 1066 1041 1011 785 429
9 384 5.4 1095 1090 1080 1066 1048 884 606
10 427 6.0 1084 1086 1080 1078 1068 956 741 422
Model GW52000-25 GW52000-50 GW52000-80 GW52000-100 GW52000-125 GW52000-150 GW52000-200
Factor 0.25 1 2.56 4 6.3 9 16
Terminology Pi(Motive pressure) Pc(Outlet pressure) Qi(Motive Flow) Qs(Suction volume) Wp(Suction Water Power) Ps(Suction pressure)
unit barg barg m3/h m3/h kw 1bar

Capacity=(Data of GW52000-50)*f

The data listed in the table are standard, if customer's condition deviates from the above please contact us to satisfy the requirement

Gas Jets Eductor Applications

Gas exhausting:

Where it is difficult or unsuitable to use mechanicalPump and pressure air or other gas are available, itIs feasible to use gas jet eductors to lift or exhaust liquid from pipeline, vessels or tanks. One of the examples is sampling in which motive gas jet through eductor nozzle and draws sampled liquid out for continuous or interval analyzing.

Gas delivery:

When the dry delivery is a must, It is applicable to use pressurized air or nitrogen to transport solids. Granular solids enter into the suction chamber under vacuum effect produced by gas jet, mix and move with gas through a diffuser to increase gas-solids mixture pressure. Gas and solids are separated after reaching to the reception point.

气水喷射器
气固喷射器

Ultrasonic Gas Ejector

In the so called high pressure ejectors, vacuum entrainment and momentum exchange are realized by ultrasonic jets of motive gases. This process is able to elevate the pressure of suctioned fluid from low to a medium point and be delivered.. General applications are always found in coal gas, natural gas and steam heat recovery and reuse. In some cases, it can be an alternative to a part of mechanical compressor.

Ultrasonic Gas Ejector Performance Data

Air GW63160-25 GW63160-50 GW63160-75 GW63160-100
Pi Pc Gi Gs Gi Gs Gi Gs Gi Gs
2.5 1.05 27 86 107 343 427 1374 1042 3354
2.5 1.11 27 43 107 171 427 683 1042 1667
2.5 1.15 27 0 107 0 427 0 1042 0
3 1.09 32 85 128 338 512 1352 1250 3302
3 1.15 32 42 128 169 512 676 1250 1650
3 1.20 32 0 128 0 512 0 1250 0
4 1.17 43 82 171 329 683 1314 1667 3208
4 1.23 43 43 171 171 683 683 1667 1667
4 1.29 43 0 171 0 683 0 1667 0
5 1.25 53 80 213 320 853 1282 2083 3129
5 1.32 53 40 213 160 853 640 2083 1563
5 1.38 53 0 213 0 853 0 2083 0
10 1.68 107 73 427 291 1707 1162 4167 2838
10 1.76 107 36 427 85 1707 580 4167 1417
10 1.85 107 0 427 0 1707 0 4167 0
Terminology Pi(Motive pressure) Pc(Outlet pressure) Qi(Motive Flow) Qs(Suction volume) Wp(Suction Water Power) Ps(Suction pressure)
unit barg barg m3/h m3/h kw 1bar

Capacity=(Data of GW52000-50)*f

The data listed in the table are standard, if customer's condition deviates from the above please contact us to satisfy the requirement

Gas Jets Gas Eductor

GW52000 Gas Jets Gas Eductor Performance Data

OutLet Pressure 1.02 1.03 1.04 1.06 1.08 1.1 1.12 1.14 1.16 1.18 1.20
Pi Qi Gi Suction Volume
1.25 130 1.7 235 206 176 110 40
1.30 136 1.77 251 227 202 147 87 24
1.35 141 1.84 265 245 223 176 124 69 11
1.40 146 1.91 277 259 240 199 153 104 52
1.45 151 1.98 288 273 256 219 178 134 87 38
1.50 157 2.04 299 285 269 236 200 160 116 71 24
1.55 162 2.11 308 296 282 252 219 182 142 100 56 11
1.60 167 2.18 318 306 293 266 236 202 165 126 85 42
1.65 172 2.25 327 316 304 279 251 220 186 149 110 70 28
1.70 177 2.32 335 325 315 292 265 237 205 170 134 95 55
1.75 183 2.39 343 334 324 303 279 252 222 190 155 118 80
1.80 188 2.45 351 343 334 314 292 266 238 208 175 140 104
1.85 193 2.52 359 351 343 324 303 280 254 225 194 160 125
1.90 198 2.59 367 360 352 335 315 293 268 241 211 179 146
Modle GW52000-25 GW52000-50 GW52000-80 GW52000-100 GW52000-125 GW52000-150 GW52000-200
factor 0.25 1 2.56 4 6.3 9 16

Capacity=(Data of GW52000-50)*f

The data listed in the table are standard, if customer's condition deviates from the above please contact us to satisfy the requirement