Home

Library

Technical Literature

Ejector Working Principle, Suction Performance and Dimensions

Ejector Working Principle, Suction Performance and Dimensions

The ejector’s patent is titled “High-Efficiency Ejector.” It efficiently transfers oxygen or other gases in aeration tanks of different depths and is used to treat municipal sewage and industrial wastewater, particularly high-strength wastewater.

Pressurized motive fluid enters the ejector and forms a high-speed jet in the injection chamber. The resulting local pressure drop draws gas or liquid through the suction port, where it mixes with the motive fluid. The mixture slows as it passes through the diffuser and its pressure recovers. The outlet pressure remains below the inlet pressure.

The ejector mixes efficiently over a wide operating pressure range. A small pressure difference between the inlet and outlet can generate the negative pressure needed for suction. All models have been tested with clean water and wastewater, and hydraulic performance curves are available.

GW Series Ejector Performance

Table 1. GW Ejector Air Suction Performance
No. Model Motive flow rate (m³/h) Inlet pressure (kg/cm²) Installed power (kW) Maximum air suction flow rate (m³/h) Material
At 1 atm suction pressure At 1.6 atm suction pressure
1 GW200 7.5~33 0.35~7.03 0.07~6.32 37 94 304/316/316L
2 GW300 17~74 0.35~7.03 0.16~14.74 56 142 304/316/316L
3 GW400 30~103 0.35~4.22 0.29~11.84 111 284 304/316/316L
4 GW600 56~192 0.35~4.22 0.53~22.07 229 586 304/316/316L
5 GW800 82~303 0.35~4.92 0.78~40.60 383 980 304/316/316L
6 GW1200 140~480 0.35~4.92 1.24~64.31 608 1556 304/316/316L
7 GW3600 274~1010 0.35~4.57 2.61~125.70 1277 3269 304/316/316L

GW Ejector Selection Guide

Table 2. GW Ejector Water Suction Performance
No. Model Motive flow rate (m³/h) Inlet pressure (kg/cm²) Installed power (kW) Maximum water suction flow rate (m³/h) Material
1 atm, water density 1 kg/L
1 GW200 8~35 0.35~7.03 0.08~6.70 2.3 304/316/316L
2 GW300 17~77 0.35~7.03 0.16~14.74 4.6 304/316/316L
3 GW400 39~104 0.35~4.22 0.37~11.95 10.6 304/316/316L
4 GW600 67~206 0.35~4.22 0.64~23.67 10.6 304/316/316L
5 GW800 96~314 0.35~4.92 0.92~42.07 20 304/316/316L
6 GW1200 151~498 0.35~4.92 1.44~66.73 31.8 304/316/316L
7 GW3600 318~1045 0.35~4.57 3.03~130.06 66.7 304/316/316L

Factors affecting ejector performance

GW Series Ejector Features and Materials

  • Easy to install and flexible in layout.
  • Stable and reliable over extended operation, with minimal routine maintenance.
  • High efficiency, low investment and energy consumption.
  • The operation noise is low and the suction process is pollution-free.
  • Long service life, easy management and maintenance.
  • Draws in gas or liquid when supplied with the required motive-water flow and pressure.

GW ejector is made of SUS304, SUS316 or SUS316L stainless steel, which is corrosion-resistant, wear-resistant, high-temperature resistant, pressure-resistant and oxidation-resistant.

Field installation of GW Series ejectors
Field installation of GW Series ejectors

GW Series Ejector Design and Installation Dimensions

GW Series ejector dimensional drawing showing L, D, K and the flange bolt pattern
GW Series ejector dimensional drawing showing L, D, K and the flange bolt pattern
Table 3. GW Ejector Mounting Dimensions and Suction Port Sizes
No. Model Nominal diameter DN Mounting dimensions Suction port diameter Dn
L D K n-φd Dual suction ports Single suction port
1 GW200 50 267 140 110 4-φ14 25×2 G1.25"
2 GW300 80 396 190 150 4-φ18 40×2 G2"
3 GW400 100 551 210 170 4-φ18 50×2 50
4 GW600 125 665 240 200 8-φ18 50×2 50
5 GW800 150 766 265 225 8-φ18 50×2 65
6 GW1200 200 1075 320 280 8-φ18 50×2 100
7 GW3600 300 1576 440 395 12-φ22 80×2 150

Product Photos by Model