Home
Library
Technical Literature
Technical innovation of aeration process
Technical innovation of aeration process
Practice has proved that after a long period of operation of the currently commonly used blast aeration system, due to the aging and cracking of the aeration head, the blocking of the diffusion holes, and the wear and tear of the blower, the operating and maintenance costs of the sewage treatment plant have become an upward trend. So, there are two main questions:
1. Design and operation power consumption
Based on the considerations of clogging, aging and cracking of the aeration tube/head, whether using a mesopore or micropore aerator, many design engineers, when determining the size of the high-speed blower capacity, always enlarge the design model of the blower on the basis of meeting the requirements for maintaining the aerobic state in the pool to ensure that the required aerobic state in the pool can be maintained when the aerator is blocked or aged. The usual practice is to set the oxygen utilization rate in the air between 6% and 10%. Increasing the water depth seems to improve it, but increasing the water depth means increasing the wind pressure, that is, increasing the power requirements of the blower, so it is limited by the water depth.
Solution:
The GW jet aerator of Chengdu Green Water Technology Co., Ltd. was used for transformation, and high-speed fans and complex piping systems were replaced with high-efficiency jets, efficiency-enhancing nozzles and low-speed water pumps. The amount of air that the ejector needs to inhale is tailored to the specific oxygen demand. After the air is mixed for the first time in the jet, the supersaturated oxygen gas-liquid mixture is sprayed into the pool through the synergist nozzle, attracting water equivalent to 4 to 5 times the flow rate of the water pump in the pool to mix with it.
Water-water mixing effectively utilizes the water head energy and has excellent mixing and stirring effects. The working power of the ejector is not limited by the water depth. SAE increases with the increase of water depth, and the power efficiency also increases and is not blocked or aged.
The oxygen utilization rate during design is as high as 30% or more. The power of the modified water pump can be 30% to 50% lower than the power of the originally installed blower.
Comparison of supporting power required for GW jet aeration and blast aeration system
Supporting power required for blast aeration (kW)2. Maintenance and start-up rate of aeration system
In addition to the high energy consumption issues caused by aging aeration systems, a significant concern is the downtime required to repair and replace aeration systems. Repair and replacement can only take a day, but the recovery of the biochemical system may take a week or a month. Overall, the operating rate and water treatment capacity of the aeration system and even the entire water treatment system are greatly reduced, and it will also cause overload problems in adjacent sewage treatment plants.
Solution:
Chengdu Green Water Technology Co., Ltd. can provide a jet solution of ejector + booster nozzle, which can be installed at any depth in the pool within one day without draining the water in the pool.
Since the ejector and booster nozzle are made of stainless steel, the performance is stable for a long time and basically requires no maintenance.
When servicing the water pump, it is not necessary to stop the operation of the water treatment system.
water pumpventuri jetBlower
Booster nozzle
Our jet solutions are suitable not only for small and medium-sized sewage treatment but also for large and medium-sized urban sewage treatment plants.
Chengdu GreenWater Co.,Ltd.